KN45

Regenerative turbine electric pumps for cutting and welding

Application Field
Immagine del prodotto Simaco KN45
Product Details

KN

KN45

Regenerative turbine electric pumps for cutting and welding

NameTypeP2 (kW)
50Hz / 60Hz
Dual Frequency
(50/60Hz)
Q max
50Hz
H max
50Hz
DN
KN453 ph0,45 / 0,68V33463/8G
KN451 ph0,45 / 0,68V33463/8G

Characteristics

Continuous duty S1.
2 pole motor.
Insulation class F.
Protection IP42 (IP 54 on demand).
IE3 efficiency class for 3-phase motors >0,75 kW.
Working tolerance: +/- 10%.
Liquid temperature (with anti-freeze additive): -20 °C / +90 °C.
Limit ambient temperature: +40 °C.
Normal priming, manometer suction up to 5m.
For clear waters and non-aggressive dilutions, without abrasive substances.

Hydraulic characteristics for water 20°C at nominal pump speed. Tolerance according ISO 9906-2012

On request

Special voltages.
60Hz version.
Dual-frequency.
Special fluids with temperature <180°C.
UL/CSA.

Dimensions

specifica tecina KN45

Hydraulic performance

specifica tecina KN45

Executions

specifica tecina KN45